What does IEC 62745 require for wireless remote controls?

IEC/EN 62745 defines behaviour requirements for wireless control systems of machinery: unintended operation, data integrity, signal loss and supply loss.

IEC/EN 62745:2017 (+A11:2020) defines what has to happen in which event in the wireless control systems of machinery: the prevention of unintended operation, the blocking of unauthorised use, data integrity, and the behaviour on loss of communication and on loss of supply. It does not determine how the radio link works, on which frequency it transmits or what its range is. It is a Type B2 standard, applied in addition to IEC 60204-1, and it covers portable control stations carried by the operator in particular.

The five headings of the standard

It is not enough on its own: which standard covers what

The standard is Type B2; it relates to a particular kind of safety component and is applied together with the machine's own Type C standard. That is, on a crane 62745 does not take the place of the machine's own standard, it is added alongside it.

StandardIts scopeWhat it answers on the remote control
IEC/EN 62745Wireless control behaviourPairing, data integrity, signal loss
IEC 60204-1Electrical equipment of machinesStop categories, control circuit
EN IEC 60204-32Lifting machinesInterlocks, emergency stop
EN 13557Crane control devicesControl station and stopping

What the standard does not determine

Seeing this number on a declaration of conformity does not answer these questions: in which band does the device transmit, what is its range, what is the ingress protection rating of the housing, what level is its electromagnetic immunity. These are the subject of separate standards and separate declarations; EMC compliance and wireless control behaviour do not take each other's place. Nor does the standard impose a performance level; the level required is determined by the risk assessment of the machine. A common mistaken assumption follows from this: reading the number 62745 on a declaration does not show that the remote control has reached a particular safety level and does not stand in for the risk assessment of the machine. Neither does conformity make the wireless link take the place of the wired emergency stop circuit on the machine.

How to verify it when buying

Look not at the marketing text on the product page but at the standard number and version listed in the declaration of conformity; the version is the detail most often skipped. The most practical indication that the standard has really been applied is that the manual describes the signal loss timeout, the restart behaviour and the behaviour of a button held down at power-up. If there is no such description, observe these yourself during the acceptance test and write the result into the machine file.

The division of responsibility is clear: the manufacturer gives the declaration, the user does the acceptance test. The manufacturer is obliged to design the behaviour and to describe it in the manual; the person who will see that the installation really shows this behaviour on site, however, is you. Without a commissioning record a claim of conformity stays half made, because the same receiver goes on being a device that conforms to its declaration even when it has been wired wrongly.

This information is a general explanation of the scope of the standard. The conformity of a particular product to IEC 62745 can only be verified from the declaration of conformity and the technical file of the manufacturer.