Memory Reset

This is erasing the taught upper limit and making the system ready for calibration again. On the GS740-3P the power is cut, about 5 seconds are waited, the blue wire is connected to GND first and then power is applied; about 8 seconds after power-up the memory is erased and the actuator signals this with a movement.

The order of the steps is not accidental. Cutting the power and waiting a short time ensures the controller shuts down completely; connecting the blue wire to GND before applying power ensures that the erase request is read at the moment of power-up. If the order is broken, the system counts this as a normal calibration trigger and the memory is not erased.

Erasing is needed in the following cases:

After the erase operation the system is in an untaught state. Instead of running it straight away, first re-establish the cable tension, then carry out the upper limit teaching step. A new teaching done without correcting the tension brings the same problem back in a short time.

This procedure is specific to the GS740-3P, and the blue wire is present only on this product.

Knowledge Center