Category 3 Architecture

A redundant, dual-channel circuit structure in which the safety function is not lost because of a single fault. Some of the faults are also detected; however, accumulated faults can lead to loss of the function. For radio-controlled crane stopping, this architecture and performance level d are the common target.

The essence of the structure is two independent channels. Each channel can execute the stop command on its own; even if one fails, the other stops the machine. Cross monitoring is usually added on top, so the channels compare each other's state and report an inconsistency as a fault.

A radio remote control set with relay contact outputs does not build this architecture on its own; you create the redundancy in the panel. Instead of relying on the remote control output alone, guarantee the critical stop over a second independent path as well and test the function at defined intervals.

Knowledge Center